Product Specification:
Shape / Structure
Enclosed Limit switches
service life
General type
Operating mechanism
Snap action
Actuator
Panel mount roller plunger
Frequency
50/60 Hz
Switching mechanism
Self-reset mechanism
Contact configuration
Single-Pole, Double-Throw type
Contact form
SPDT
Load
General load
Ratings (AC): Non-Inductive load
Rated voltage: 125 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
Rated voltage: 250 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
Rated voltage: 480 VAC, Resistive load: 2 A (NC) 2 A (NO)
Ratings (AC): Inductive load
Rated voltage: 125 VAC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 2.5 A (NC) 2.5 A (NO)
Rated voltage: 250 VAC, Inductive load: 2 A (NC) 2 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO)
Ratings (DC): Non-Inductive load
Rated voltage: 8 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO)
Rated voltage: 14 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO)
Rated voltage: 30 VDC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
Rated voltage: 125 VDC, Resistive load: 0.4 A (NC) 0.4 A (NO), Lamp load: 0.4 A (NC) 0.4 A (NO)
Rated voltage: 250 VDC, Resistive load: 0.2 A (NC) 0.2 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO)
Ratings (DC): Inductive load
Rated voltage: 8 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO)
Rated voltage: 14 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO)
Rated voltage: 30 VDC, Inductive load: 1.5 A (NC) 1.5 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO)
Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load: 0.05 A (NC) 0.05 A (NO)
Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load: 0.03 A (NC) 0.03 A (NO)
Explanation
The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current.
Inrush current
NC: 15 A
NO: 15 A
Protective circuit
Classification of protection against electric shock: Class II (Double insulation)
Short-circuit protective device: 10 A fuse type gI or gG (IEC269)
Ambient temperature
Operating: -10 to 80 CEL
(with no icing or condensation)
Ambient humidity
Operating: 35 to 95%RH
(with no icing or condensation)
Characteristics
Permissible operating speed
0.1 mm/s to 0.5 m/s
Permissible operating frequency (Mechanically)
120 operations / 1 minute Max.
Permissible operating frequency (Electrically)
30 operations / 1 minute Max.
Contact resistance
15 mOhm Max. (Initial value)
(Measuring method is contact resistance meter.)
Insulation resistance
Between each terminal of the same polarities: 100 MOhm Min.
Between live-metallic part and ground: 100 MOhm Min.
Between each terminal and non-live-metallic part: 100 MOhm Min.
(at 500 VDC Megger)
Dielectric strength
Between each terminal of the same polarities: 1,000 VAC
Between live-metallic part and ground: 2,000 VAC
Between each terminal and non-live-metallic part: 2,000 VAC
(50/60 Hz for 1 min)
Durability (Mechanically)
10,000,000 operations Min. (No load)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Durability (Electrically)
500,000 operations Min. (Resistive load 10 A at 125 VAC)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Pollution degree
3 (EN60947-5-1)
Vibration resistance (Malfunction)
Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Shock resistance (Destruction)
1,000 m/s2
Shock resistance (Malfunction)
Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.
Degree of protection
IEC60529 (JEM): IP67
NEMA250: Type1
Applicable standard (UL)
Standard No.: UL508
File number: E76675
Applicable standard (CSA)
Standard No.: C22.2 NO.14
File number: LR45746
Applicable standard (TUV)
Standard No.: EN60947-5-1
File number: J50062486
Applicable standard (CCC(CQC))
Standard No.: GB14048.5
File number: 2003010305072162
Applicable standard (EC Directive (Low Voltage Directive) )
2006/95/EC
Mounting specification
Panel mounting, Side mounting
Operating characteristics
Operating Force (OF)
Standard value 9.81 N Max.
Release Force (RF)
Standard value 1.96 N Min.
Pre-Travel (PT)
Standard value 1.5 mm Max.
Over-Travel (OT)
Standard value 2 mm Min.
Movement Differential (MD)
Standard value 0.5 mm Max.
Operating Position (OP)
Standard value 43 +/- 0.8 mm
Package Include:
1 x NEW OMRON SHL-Q2255 Panel Mount Roller Plunger For Standard Load6 months warranty
60 days money back
Life-time support.
Our specialists will be with you during shopping and after-sell. Professional advise and any technical problem will be provided. We will respond any question within
24-hour
normally. Please allow longer time for weekend.
Our logistic team will pack your order safely, make sure the item will be arrived perfectly. And then the parcels will be pass to courier. The total dispatched time will be around
1-2 days
.
We focus on product quality, rather than packaging and marketing, in order to deliver the
finest quality
of product at a fraction cost. We believe that you would like to pay for the item cost except unnecessary costs.
Our product team will keep the products
up-to-date
, which can allows you to purchase the latest and valuable products from our stores. We believe our
Wide Product Range
will be your selection.
How should I make my payment ?
We accept
PayPal
. Your payment is protected by
Buyer Protection
.
Items will be shipped within
1-2 working days
of payment being made.
No mailing payment will be accepted.