Keyence FDQ50C FD-Q50C Clamp-on Flow Sensor - Sensor Main Unit 40A/50A Type. Condition is "New".Model
FD-Q50C
Supported pipe diameter
1 1/2" (40 A), ø44 to ø52 (mm)
2" (50 A), ø52 to ø64 (mm)
Supported pipe materials
Metal pipe/Resin pipe
*1
Supported fluids
Various liquid [i.e. water (including DI), oils, chemicals, etc.]
*1
Supported fluid temperature
0 to 85°C
32 to 185°F
(No freezing on the pipe surface)
*2
Maximum rated flow
1 1/2" (40 A): 400 L/min, 105.7 G/min
2" (50 A): 500 L/min, 132.1 G/min
Zero cut flow rate
25 L/min (Default)
*3
Display method
Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator
Display update cycle
Approx. 3 Hz
Display resolution
0.1/ 1 (Default :1) (L/min)
Response time
0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s
Repeatability
0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.
*4
(Specific to selected response time))
Hysteresis
Variable
Integrated flow unit display
1/ 10/ 100/ 1000/ 10000 (Default : 1) (L)
Integrated flow data storage cycle
Save to memory every 10 seconds
Memory backup
EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)
Power I/O connector
M12 4-pin connector
Input/Output (Selectable)
Output (ch.1/ch.2)
Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less
*5
Analog output (ch.1/ch.2)
4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less
*5
External input (ch.2)
Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more
*5
Power source
Power supply voltage
20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS
Current consumption
130 mA or less (Load current excluded)
*6
Protection circuit
Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection
Environmental resistance
Enclosure rating
IP65/IP67 (IEC60529)
Ambient temperature
-10 to +60 °C
14 to 140 °F
(No freezing)
Relative humidity
35 to 85 % RH (No condensation)
Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm
0.06"
, 2 hours in each of the X, Y, and Z directions
Shock resistance
100 m/s
2
, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material
Sensor main unit
PPS/PES/PBT/SUS303/SUS304/SUSXM7
Sensor surface
Rubber
Mounting bracket
SUS304/PA/POM/SUSXM7
Weight